Coverage
rates
and coating areas
The
coverage rate is 5m²
per litre which allows for the two
coats. The coverage rate will reduce for very
porous surfaces, such as sandstone, and an allowance
of upto 30% should be made.
When
coating a wall it is usual to coat from ground
level up to a height of 2.5mtrs - this is the
maximum height that most graffiti vandals can
reach. You may choose to coat to a higher level
particularly if there are adjacent surfaces
onto which the vandals can climb.
Important
Do not apply the coating if the temperature
has fallen or is going to fall below 5ºC for
a 24 hour period following application.
Clean and coat a small test area to confirm
suitability - particularly on polished or gloss
surfaces.

|
Application
Instructions
- Clean
the surface to be coated to remove surface
dirt and grime. Allow the surface to dry.
- Put
on the safety glasses and gloves provided
with the kit.
- Stir
the coating.
- Spray
onto the surface using the spray applicator
provided. Ensure that the surface is saturated
- this will be the point at which the coating
liquid starts to run down the wall. Do not
over apply.
- Allow
the coating to dry - this may take up to 4
hours.
- Stir
the coating again and apply the second coat.
This will require less coating liquid than
the first.
- Empty
any remaining coating liquid back into the
original container for later reuse.
- Clean
the applicator with clean water. Wash the
interior, re-pressurise and spray the water
through the nozzle for one minute to clean.
Empty, dry and then store the container for
reuse
|